A Couple Of Clear-Cut Practices Available For Thiazovivin Exposed

Матеріал з HistoryPedia
Перейти до: навігація, пошук

We eluted the RNA with 15 ?L of RNase-free water, and which was all used in reverse-transcription. 3. RNA quantification Quantification of RNA isolated from dilute samples such as plasma/serum can be very difficult [12]. Even when using a carrier to enhance the isolation efficiency, attempts to measure RNA concentration by standard spectrophotometry often fail due to the detection limit of this method. As a consequence of these difficulties in quantifying the RNA concentration of dilute solutions, it is in many cases not possible to use equal amounts of template RNA for each sample in the subsequent reverse transcription step. Cell Cycle inhibitor Because large amounts of sample are not always available, often the only alternative is to use equal input volume of RNA. The most commonly used approach here is the use of an exogenous micro RNA (cel-mir-39 in our study, used as endogenous housekeeping control) of known quantity [13]. We then reverse-transcribed the total RNA into cDNA, according to the manufacturer's recommendations of reverse transcriptase (Toyobo, Tokyo, Japan). Simultaneously, we reverse-transcribed endogenous reference cel-mir-39 RNA into cDNA in a same reaction tube, the primer sequences of which: 5'-GTCGTATCCAGTGCAGGGTCCGAGGTATTCGCACTGGATACGACCAAGCT-3'. All the primers were synthesized by Biotech Co. (Shanghai, China). The RNA samples were pre-heated before reaction, and then put on ice immediately. The reaction was set up in a reaction volume of 20 ?L including 2 ?L 5��transfer mix, 1 ?L RT enzyme mix, 2 ?L primer mix (with final primer concentration of 1 ?M) and all the 15 ?L pre-heated RNA we extracted. The reaction conditions: 37��, 45 minutes, 95��, 5 minutes. A final cDNA volume of approximately of 20 ?L was obtained, which was stored at -20��. 4. Quantification and analysis of cDNA The cDNA samples were then used for real-time PCR measurement with specific primers. The primers for SNP Rs8130833 and cel-mir-39 were designed using Primer 3 software (Table 1). The primers were synthesized by Biotech Co. In this study, we selected primer with the SNP of Rs8130833 to realize the relative quantification of PLAC4 mRNA. The quantification reaction was set up in a reaction volume of 10 ?L including 5 ?L 2��SyBr-Green mix, 0.2 ?L 50��ROX, 1 ?L cDNA, 1 ?L primer mix (the final primer concentration was listed in Table 1), The PCR was run for 45 cycles of denaturation at 95�� for 2 minutes, annealing at 96�� for 15 seconds and elongation at 60�� for 45 seconds. After 45 cycles, a melting curve analysis was carried out (65�� to 95��) to verify the specificity of amplicons. The quantification reactions were performed on ABI PRISM 9700. To minimize stochastic effects, all amplification reactions were run in triplicates. The threshold cycles (Ct) were calculated automatically using the CFX manager software (Bio-Rad, Hercules, CA, USA).