This Is The Quick Technique To Be Successful Together With 3-Methyladenine

Матеріал з HistoryPedia
Перейти до: навігація, пошук

The samples were then processed in the microflex LT (Bruker Daltonik GmbH) mass spectrometer equipped with a 20-Hz nitrogen laser. The spectra were recorded in the positive linear mode as described elsewhere [10]. To identify microorganisms, the raw spectra obtained 3-Methyladenine in vivo for each isolate were imported into BioTyper software, version 2.0 (Bruker Daltonik GmbH), and analysed without any user intervention, using default parameter settings, by the standard pattern matching algorithm against the spectra of 3294 species in the Biotyper database, version 3.0 (updated October 2008). The reference database consisted of 126 main spectra encompassing 46 Staphylococcus species and subspecies, as depicted in the dendrogram generated from the corresponding spectra (Fig.?1). The results of the pattern matching process were expressed as log(score) values in the range 0�C3, using values of ��2.0 for identification to the species level and values of between Sunitinib datasheet the spectra from the region in the range 2?000�C11?000?Da, with the highest-intensity peaks being consistently in the range 3000�C10?000?Da. On this basis, the log(score) values obtained by MALDI-TOF MS correctly identified all but three staphylococcal isolates at the species level [log(score), ��2.0], as subsequently confirmed by the rpoB gene sequence-based molecular analysis. S.?aureus isolates were 100% correctly identified. A correct identification was obtained in 99.1% (332/335) of the CoNS isolates. Among the three species that most frequently cause disease in humans or are isolated most frequently from human samples, S.?epidermidis (n?=?199), S.?hominis (n?=?49) and S.?haemolyticus (n?=?36), MALDI-TOF MS gave a correct identification in 99.6% (283/284), with one S.?epidermidis isolate being misidentified as S.?hominis (subsp. novobiosepticus) [log(score)?=?2.062]. Of two other isolates not correctly identified, Ceftiofur one was identified as Staphylococcus simulans) by MALDI-TOF MS [log(score)?=?2.084] and as S.?warneri by rpoB sequencing, and, interestingly, the other isolate was identified as S.?haemolyticus by MALDI-TOF MS [log(score)?=?2.252] and as Staphylococcus pettenkoferi by rpoB sequencing (Table?1). As recently stated by Dupont et?al. [11], misidentification often results from the heterogeneous behaviour of the CoNS population obtained from clinical specimens, particularly when conventional phenotypic identification means are employed. In two different studies published in 2008, the use of current automated biochemical tests [the Phoenix and Vitek 2 (bioM��rieux, Marcy l��Etoile, France) (Becton-Dickinson, Becton-Dickinson Biosciences, Franklin Lakes, NJ, USA) systems] gave correct identification rates for CoNS of only 90.5% and 87.