Warning Signs On The Temsirolimus You Ought To Know

Матеріал з HistoryPedia
Перейти до: навігація, пошук

After the addition of CT-scans Sirolimus only observer 4 (skeletal radiologist) showed a significantly higher kappa value than the three other observers. All four observers stated that they had difficulties in distinguishing between Schatzker types I (split fracture) and II (split and compression) in four cases (8.9%) (Fig. 4) and between types V (bi-condylar with methaphysis intact) and VI (methaphysis broken) in two of the cases (4.4%) when classifying with plain radiographs. When classifying on the basis of CT-scans all four observers stated that they did not have any problems in classifying fractures. Inter-observer reliability of the Hohl classification (Table 1) was ��moderate�� with plain radiographs and improved to ��good�� with CT-scans. Intra-observer reliability (Table 2) was ��moderate�� with plain X-rays and improved to ��good�� with computed tomography scans. The skeletal radiologist (observer 4) showed a significantly better reliability for plain radiographs and CT-scans than the other three observers. In four cases (8.9%) all four observers found it difficult to distinguish between Hohl types A (split fracture) and C (split and compression) (Fig. 4), and, in four cases (8,9%), between types C selleck (uni-condylar split and compression) and F (bi-condylar) when classified on the basis of plain radiographs. When classifying on the basis of CT-scans all four observers stated that they did not have any problems in classifying fractures. When classified on the basis of computed tomography scans statistical analysis showed a significant improvement of inter-observer reliability for all three classification systems (Table 3) (p?CYTH4 inter-observer reliability when classified solely on the basis of plain radiographs. After the addition of computed tomography scans inter-observer agreement significantly improved to ��good�� in all classifications. Intra-observer reliability with plain X-rays was ��good�� for the OTA/AO and the Schatzker classification and ��moderate�� for the Hohl system. When classified on the basis of CT-scans all three systems showed ��good�� intra-observer agreement. Statistical analysis showed no significant difference regarding inter- and intra-observer agreement between the three classifications. Several other studies[3], [10]?and?[20] have evaluated the reliability of the OTA/AO, Schatzker and Hohl classification on the basis of plain radiographs. Their results[3], [10]?and?[20] are comparable with the data of the presented study. In contrast to the results of our study, Chan et al.